We need to pay more attention to monitor maintenance



                  (The Perlong Medical brand - JP2000-09 ultra-thin multi-parameter monitor)

       Monitor (ECG, patient monitor, multi-parameter monitors) shouldering the mission "irreplaceable" It is one of the basic hospital medical equipment, but also hospitals indispensable equipment in the hospital. Monitor for control and monitoring instruments, ECG, body temperature, blood pressure, oxygen saturation and heart rate, breathing and other parameters of the patients Monitor the proper use and maintenance of the instrument will be directly related to monitor instrument life and monitor the conservation work will reduce accidents and reduce hospital costs.

      Next, the Perlong medical need to monitor maintenance precautions explain.
      Monitor ambient temperature should preferably 20 to 35 ° C, humidity 50% to 80% better power should be single-phase 220V three-wire, with a separate ground wire, which prevents interference and to ensure electrical safety.


    Second, the monitor should be used with good ventilation environment instrument should maintain a certain distance from the wall, and attention to the monitor should not cover, so as not to affect the instrument heat. Monitor cooling bad instrument internal components can cause damage or crash.
    Never frequent switching Monitor instrument instantly turn off the machine will produce large inrush current impact, if too frequent switching opportunities seriously affect the life of the machine.
Minimize noise caused due to monitor alarm, should lower the alarm volume, The temporary unwanted guardianship items in the monitor display should be closed to create a safe and comfortable environment for patients, reduce patient unnecessary panic.

    ECG line with gauze moistened with disinfectant wipe can minimize immersion disinfection to prevent corrosion of the lead line so that the skin cracks. Oxygen sensor can not be autoclaved, also can not be soaked in disinfectant available alcohol cotton ball or soft cloth to wipe the appearance, the light tube and the receiving device.
   VI Do not pull on the lead wires, lead wires do not have to be put away in circular form. Barbaric non-plug wires, should be carefully aligned with the positioning groove, to avoid pin plug leadwires deformed or broken damaged.

   So much, I believe you need to pay attention to the maintenance of the monitor matters also have a detailed understanding If you feel you do not know or need to consult more information about the Monitor instrument, you may wish to call Perlong medical Toll Free Details consultation, or Login The Perlong medical officer to enter the product description page for more information View.
  If you have any questions, please feel free to contact us.

How much is a multifunctional food safety rapid detection analyzer

    How much is a multifunctional food safety rapid detection analyzer? The instrument is very common in the medical device market, there are several well-known medical device companies in the production and sales of which there Pulang medical. The Pulang medical main radiology equipment, Laboratory equipment, myocardial product, reagents and related products automatic washer, coagulation analyzer, full wavelength microplate reader.

    And the latest multi-parameter food safety rapid detection analyzer calibration units of measurement above the provincial report, test report and registration of software products over the provincial inspection units. Instrument using intelligent control settings, data statistical processing, auto-save, automatic printing and other functions, operation simple and intuitive data. Click on the picture below the red word more details.

   If you want to query the multifunctional food safety rapid detection analyzer how much can log on the the Perleong medical official website or call our call for questioning.

Ecg monitor in use process need to pay attention to what problem





                 (perlong medical brand - JP2000 super-thin multi-                                 parameter monitor)

    Ecg monitor (patient monitor, multi-parameter monitor) because of its unique function, efficient work efficiency makes the instrument in hospital more widely used, the popularity of ecg monitor is a timely monitoring patient vital signs and provide important basis for clinical important medical equipment. If it is not properly used not only for the patient can't be accurately effective monitoring, even can cause damage to the instrument, the instrument can't normal use. Therefore, ecg monitor when use need to pay attention to want to use the methods, the following perlong medical introduce you to monitor ecg, blood pressure and blood oxygen measurement in matters that should pay attention to:
 
First, ecg monitoring matters needing attention

(1) the pretreatment of the skin is very important, first of all to the patient's skin cleaning. First used in the measurement of ethanol patients area of surface cleaning, to skin clean the purpose is to remove the human body skin cutin layer and sweat be soiled, prevent electrode piece of bad contact. You have to be careful with ethanol in the volatile dry clean only after they will electrode plate stick this part, in order to avoid the electrode slice off.

(2) due to the usage of the electrode plate is very large, long-term application will fall off, also can affect the accuracy and monitoring quality. So click bill should be replaced periodically once (suggest 3-4 days).

(3) will lead wires shall be secured told patients and families don't pull electrode wire and cable.

(4) if the monitoring found that special abnormalities, should ask professional inspection, diagnosis, to ensure accuracy.

Second, the oxygen measurement problems needing attention:
(1) blood oxygen probe should try to avoid using strong, if can't avoid, can use the opaque cloth cover the oxygen probe, in order to avoid the light to the measurement of blood oxygen produce interference which can lead to inaccurate measurement.

(2) the right operation method should be probe line on the back side, pay attention to patients body warm, remove nail polish, not will be clipped to tie a blood pressure cuff belt body so that patients in the measurement of blood pressure cuffs air pressure arm will affect oxygen measurement.

(3) if you can see GuanLiang luminescence, and can't measure blood oxygen value, can use alcohol sponge or soft cloth to wipe luminous tube and receiving tube.

Third, blood pressure measurement problems should be paid attention to:
(1) blood pressure measurement should be used with normal sleeve cuffs, squeeze out the air; Sleeve belt bind should stretch the right.

(2) the cuffs unfolds in the patient's elbow should be winding of 1 ~ 2 cm place, elastic degree can be inserted to 1 ~ 2 refers to the advisable. Too loose can lead to pressure on the high side, Bind may cause pressure on the low side, also can make patients feel uncomfortable, but also affects the patient's arm blood pressure recovery.

(3) the sleeve band and heart level position height difference, sleeve with inappropriate, leak, and sleeve with connecting pipe joint leakage, etc can cause blood pressure measured value is not allowed. Sleeve strap position as far as possible with the heart at the same level.

(4) don't bit body or traumatic physical measurement of blood pressure, avoid to cause blood backflow or wound bleeding.

(5) in the daily monitoring without frequent measurement of blood pressure, blood pressure measurement should be changed to manual mode, avoid to affect instrument life. Condition allows, the best interval 6 ~ 8 h change a monitoring site. To prevent the continuous monitoring of the same place, give patients caused unwell and skin damage.

   After above the ecg monitor in use process should pay attention to the introduction of matters, I believe you the ecg monitor use has a lot of understanding, if you want to know more information of ecg monitor, you can land perlong medical's official website to see to understand, or call page free consultation telephone consultation.


 



Monitor should be how to maintenance and maintenance

     Monitor is a kind of used for patient physiological parameter monitoring and control and regulation in numerical inside, if overweight can give warnings of a kind of medical instruments, monitor can also be called: multiparameter monitor, patient monitor, ecg monitor, etc. The equipment is widely used in the operating room, critically ill patients, premature, newborns, delivery room, etc. Monitor in addition to measuring and monitoring physiological parameters outside, still can be used for monitoring and processing drug and the use of before and after surgery. Is a kind of function is very powerful instrument. With the modernization of the hospital development, more and more monitor will enter the clinical, become ward the most commonly used one of the medical equipment. Therefore, the use of the monitor is proper and maintenance and maintenance is to extend instrument life important factors.

   If well monitor maintenance and maintenance work also helps to ensure that the monitor good working condition, reduce accidents, which will reduce the cost of the hospital. The small make up for everybody introduction monitor maintenance and maintenance in the following aspects:


   First, main engine maintenance and maintenance:
   Monitor is usually work continuously, so the use of continuous time is very long so it is easy lead to high temperature within the instrument, so the first thing to do is do instrument inside and outside clean, to ensure that the instrument has good cooling and ventilation. Regular inspection host on the screen, clean the dust, at the same time, still need to check the operation panel, the surface of the screen, if there is dirt on with alcohol clear dirt, to ensure that equipment clean. Regular apart machine shell (suggest every half year or once a year), to the instrument internal cleaning. At the same time can be on the internal parts for inspection.

  Second, the sensor maintenance and maintenance:
  Due to the sensor often in programs, so sensor is also very easy to damaged parts. So should also do maintenance work. Medical staff correct operation and maintenance of monitor and sensor is also very important. To monitor the parts operating personnel are not used force ye, pull, fall, collision, etc. Such as noninvasive blood pressure cuffs, without binding in patients, the instrument can't measurement, or it will damage the inflatable balloon. Sensor probe on easy to be infected by the patient's sweat, blood, etc. Various kinds of stains, in order to avoid probe corrosion and affect the measurement, still need regular according to user's manual provides methods for cleaning probe.

  Third, the system of maintenance:
  If the monitor system Settings inappropriate or mistakes, also can give health care workers into trouble. So often inspection and maintenance of the instrument system to ensure the reliability and safety of care. Market sales monitor has a lot of kinds, in the system setting method also can have certain differences, but most of the monitor instruments have these aspects: the patient information in the information of the should pay attention to "the patient is type" choose to correct. Generally divided into adults, children and babies, they were used respectively to different measurement scheme, if medical personnel choose wrong mode will affect the measurement accuracy, can't even measurement.

   From the above content we can see that monitor maintenance and maintenance is very important, instrument used correctly on the life is very important, so medical personnel to deal with these aspects should be pay attention, if you want to know more about monitor (multi-parameter monitor, patient monitor, ecg monitor) instrument information, you can login perlong medical website view, in addition, perlong medical production many kinds of medical equipment is the first choice for clinical brand, specific product information, please login perlong medical's official website to view.


2013年1月24日星期四

Portable ECG patientmonitor manufacturers | portable ecg monitor price | portable ecg monitor quotation

    Ecg monitor (patient monitor,) are widely used, it can monitor several human body the main physiological signal, it is suitable for severe patient monitoring work. Of course, the patient will have sudden happens, portable ecg monitor appearance, will happen to can solve the emergencies happen.

   The portable ecg monitor manufacturers are those? Perlong medical is a representative brand, she's one JP2000 super-thin portable ecg monitor, humanized design, after all the accessories fence without disassemble can on the fence. In addition, for the medical personnel to provide a convenient and rapid accessories storage place, make the machine mobile use more convenient, especially for rescue, etc to save valuable time, also can completely avoid the monitor in the panic in the process of moving to oxygen probe contour precision parts of all kinds of impact damage;

   And remote wireless communication system, can acquisition ecg, blood pressure, blood oxygen, respiration, pulse, body temperature and vital signs information effectively remote data transmission, real-time remote control for patients in the first time to win the precious opportunity to treatment, can connect the central station, support wired and wireless networking, is the present domestic market independent development of the thinnest of portable ecg monitor.




(perlong medical brand - JP2011-01 portable ecg monitor (portable ecg monitor).

   If you have any question about our article , you can click the online message window, then there will be friendly online service , she can solve your question.

CPAP machine

   Definition: Continuous positive airway pressure, commonly called CPAP, is a type of respiratory support used in adult and pediatric patients. In premature babies, CPAP is delivered through a set of nasal prongs or through a small mask that fits snugly over a baby’s nose.Like nasal cannula, CPAP is used to deliver constant air pressure into a baby’s nose, which helps the air sacs in the lungs stay open and helps prevent apnea. CPAP can deliver more pressure than nasal cannula, so is often used in babies who are breathing well enough on their own that they do not need mechanical ventilation, but who need more support than the cannula offers. CPAP can also be used to deliver higher concentrations of oxygen to premature babies who have trouble maintaining good oxygen levels in their blood

    Continuous positive airway pressure (CPAP) is the use of continuous positive pressure to maintain a continuous level of positive airway pressure. It is functionally similar to PEEP, except that PEEP is an applied pressure against exhalation and CPAP is a pressure applied by a constant flow. The ventilator does not cycle during CPAP, no additional pressure above the level of CPAP is provided, and patients must initiate all of their breaths. Nasal CPAP is frequently used in neonates though its use is controversial. Studies have shown nasal CPAP to reduce ventilator time but an increased occurrence ofpneumothorax was also prevalent.

    As a treatment or therapy, CPAP uses mild air pressure to keep an airway open. CPAP typically is used for people who have breathing problems, such as sleep apnea.

    CPAP also may be used to treat preterm infants whose lungs have not yet fully developed. For example, physicians may use CPAP to treat infants who have respiratory distress syndrome orbronchopulmonary dysplasia. In some preterm infants whose lungs haven't fully developed, CPAP improves survival and decreases the need for steroid treatment for their lungs.

   CPAP at home utilizes machines specifically designed to deliver a constant flow or pressure. Some CPAP machines have other features as well, such as heated humidifiers. CPAP is the most effective treatment for obstructive sleep apnea, in which the mild pressure from CPAP prevents the airway from collapsing or becoming blocked.
Perlong CPAP Machine


    Usage:
   
CPAP system is used for newborn baby with stronger spontaneous breath and slightly respiratory failure ,and applies to pediatric clinics for NCPAP oxygen uptake.

   Features:
  1.CPAP ventilation mode keeps children spontaneous breath and reduces children breathing work,  continues to provide CPAP mode of constant flow and limited pressure for newborn baby;
  2.Delivery air/O2 mixture with properly adjusted O2 concentration and continuous positive pressure to premature baby, newborn baby and child, which will highly improve the safety and efficacy of oxygen therapy;
  3.Equipped with built-in oxygen/air blender, ensuring O2 concentration adjustment to be stable ;
  4.High quality oxygen sensor can monitor real-time O2 concentration , alarm over limitation, ensure safety ofbreathing O2;
  5.Reliable CPAP control valve and advanced pressure monitoring system improve CPAP adjustment precision.





Perlong medical is preparing for Arab Health 2012 ( Dubai,UAE ) perfectly !

    As we all know , perlong medical is one of largest medical manufacturer in china. As major in medical x ray machine, hematology analyzer, clinical lab device , medical reagents, ventilator system , perlong medical has got good reputation over the world . More and more custmers have cooperation with perlong medical with pleasure.

     And now , perlong medical always insisted in quality and after sales , to give our best service for every clients.

     Recently , we are preparing for Arab Health 2012 for a long time. Perlong Booth in this Arab Health is Hall 8-8B18, at Dubai International Convention&Exhibition Centre on 28-31 January, 2013.

     And we have known the history of Arab Health, this year is now in its 38th year, is the world's longest running healthcare exhibition and congress, taking place every January in Dubai.

     With the Middle East healthcare industry worth an estimated $80 billion per year, Arab Health is truly at 'The Heart of Global Healthcare'.

    So hope to see you and have good cooperation with your company or hospital in Arab Health 2012(Dubai,UAE ).