In vitro diagnostic reagents-muscle protein introduced one red kit


     In vitro diagnostic reagents-muscle protein as one kit clinical application red introduced: help early diagnosis of acute myocardial infarction, the early diagnosis of unstable angina, testing heart surgery of the degree of damage caused by heart, myocardial infarction area estimated, after acute myocardial infarction dissolve check and intervention treatment indicators.


      CK-MB because of test results is not the same as the representation method, biochemistry analyzer SIEMENS IMMULITE 2000 test CK-MB for enzyme activity determination, measured values unit for U/L, and FIA8000 series of measurement for the quantitative analyzer immune quality determination, the unit of measurement for ng/ml. Domestic no quality determination of biochemical analyzer, so can't do P value calculation. For the measured results of CK-MB to do only correlation coefficient calculation. If considering CK-MB in SIEMENS IMMULITE 2000 fall test value > 24 U/L is the positive, and FIA8000 > 5 ng/ml as positive, will be 24 U/L and value five ng/ml do a contrast, get a coefficient 4.8, will coefficient 4.8 when into consideration, and concludes that the P = 0.45., so P > 0.05, that there was no obvious difference.


      Diagnosis was CK-MB in SIEMENS IMMULITE 2000 fall test value > 24 U/L is the positive, minimum detection limit 2 U/L; FIA8000 series immune quantitative analyzer test value > 5 ng/ml as positive, when measured values > 100 ng/ml, shows > 100 ng/ml, test value < 5 ng/ml show when < 5 ng/ml. CTnI such as described in 5.1, positive value > 1 ng/ml, negative value < 1 ng/ml. Myo in SIEMENS IMMULITE 2000 positive boundary = 70 ng/ml, test value > 70 ng/ml positive, test value < 70 ng/ml for negative, but to FIA8000 series quantitative analyzer and supporting immune creatine kinase isozyme/myocardial ctni/muscle protein detection kit red one (colloidal gold method) speaking when test value > 50 ng/ml is concrete numerical display, when test numerical > 600 ng/ml, shows > 600 ng/ml.


      In clinical trials of CK-MB positive samples to the 27 cases and the negative samples for 73 cases). CTnI positive samples for 17 cases and the negative samples for 83 cases). Myo positive samples for 17 cases and the negative samples for 83 cases. Creatine kinase isozyme/myocardial ctni/muscle protein detection kit red one (colloidal gold method) positive samples of 30 cases of accumulated.

没有评论:

发表评论